Indoor VCB

Indoor VCB

ZN85-40.5

Storage, making and breaking by motor, It can operating by handle.
Breaking short-circuit current up to 25kA.
Mini motor spring mechanism (about 30W).
Installation method: adopt two type installation method.
Sealing performance: adopt reliable sealing technical.
Incoming & Outgoing method:adopt silicon bushing to make enough insulate distance
Safe operating: there is an equipment to protect explosion.

Specifications

ZN85-40.S/T type indoor high voltage indoor vacuum circuit-breaker is used for switchgear KYN61-40.5(Z), it is most new type of power supply and distribution equipment. This product is accordance with GB1984-2003 stand. This series include: Vacuum circuit breaker truck, isolation truck and fuse truck.

Structural Characteristics

1. This vacuum circuit breaker adopts compound insulation; it can meet air distance and creepage under normal run condition, and it effectively reduces the dimension of VCB, the overall arrangement is reasonable and simple, with aesthetic appearance.
2. The operating mechanism is especially newly designed for this VCB; the outlet curve has good adaptation with requirements of vacuum interrupters. It has high reliable with characteristics of long life and easy maintenance and free-maintenance for operating mechanism.
3. This truck adopts screw rod nut push-in mechanism which can realize easy pushing-in or pushing-out of panel; compulsive mechanical interlock way is adopted; meet the Five Preventions function; suitable for varies site and the working sites which have rigorous run condition

Ambient Conditions

  1. Ambient temperature: -10℃–+40℃
    2. Relative humidity: daily average 95.monthly average 90.
    3. Earthquake intensity: 8 degree;
    4. Saturated vapor pressure: the average pressure of a day should be no more than 2.2kPa; the average pressure of a month should be no more than 1.8Kpa;
    5. The height above sea level:≤1000 m (Except special requirements)
    6. Applicable occasions should free from inflammables, explosives, corrosives and severe vibration.

Technical Data

ItemUnitValue
Rated voltagekV40.5
Rated frequencyHz50/60
Rated power frequency withstand voltage(1min)kV95
Rated lightning impulse withstand voltage(peak)kV185
Rated currentA63012501600200025003150
Rated short circuit breaking current Rated short time withstand stable current 4s rated short time withstand currentkA252525



31.531.531.531.531.5
Rated short circuit closing current(peak) Rated peak withstand current Rated dynamic stable currentkA636363



8080808080
Breaking times of short circuit breaking currenttimes20
Rated thermal stability times4
Rated operating sequence
O-0.3s-CO-180s-CO
Mechanical lifetimes10000
Rated operating voltageVDC110/220 AC110/220

See how orders move from review to dispatch.

Reception, production, testing and shipment areas are organized to keep technical requirements, work progress and delivery records aligned.
Workplace & Customer Reception

Workplace & Customer Reception

Visitors and project teams have a clear place to review requirements, drawings and delivery details before work moves forward.
Organized Production Lines

Organized Production Lines

Defined work areas and orderly material flow help teams keep assemblies, components and order information aligned.
Testing & Verification

Testing & Verification

Routine checks and functional verification are completed against approved requirements before release.
Shipment & Delivery

Shipment & Delivery

Finished orders are checked, protected and organized for traceable handover and coordinated dispatch.

Built for recognised standards

Our documentation package supports project review with internationally recognised safety, quality and environmental marks.

Technical files for your review

Access the latest catalogue, technical parameters and certification files before you finalise your specification.
Go to Download Center

Product questions, answered

Clear guidance on selection, documentation, customization and project delivery.
Please provide the application, system rated voltage and frequency, continuous load current, short-circuit level, insulation level or BIL, and the required operating duty. Also include indoor or outdoor installation, altitude, ambient temperature, pollution level, control voltage, communication requirements, quantity, destination market and applicable standard. A single-line diagram, existing nameplate or project specification will make the review more accurate.
A recloser is generally used for automatic fault interruption and service restoration on distribution feeders. A circuit breaker provides repeated fault interruption, a load break switch is intended for rated-load switching within its specified capability, a disconnector provides an isolation point, and a fuse provides single-operation overcurrent protection. The final choice must be based on load current, fault level, protection coordination, switching frequency, installation method and operating philosophy.
Confirm the voltage class, frequency, rated current, short-circuit breaking and making duties, insulation level, creepage distance, mechanical or electrical endurance, enclosure protection, control supply and auxiliary contacts. The applicable IEC, IEEE, ANSI, GB or project-specific requirement should be stated in the inquiry. The approved data sheet and drawing, rather than only a general product family name, define the final supply.
Yes, a technical comparison can be made when sufficient information is available. Please send the existing model and nameplate, general arrangement and mounting dimensions, terminal interfaces, wiring diagram, interlocks, operating mechanism and electrical ratings. Similar voltage and current ratings do not by themselves confirm mechanical or electrical interchangeability, so approval is required before replacement.
Selection should consider the system grounding method, maximum continuous operating voltage, temporary overvoltage, required protective level, system insulation level, altitude, pollution severity and creepage distance. Mechanical loading, housing material and installation orientation also matter for outdoor equipment. Provide the system and site data so insulation coordination can be reviewed as a complete set.
Customization can be evaluated according to technical feasibility, validation requirements and order quantity. Typical requests include labels and packaging, terminal arrangements, mounting dimensions, control voltages, transformer ratios, accessories, communication functions and project documentation. Customized production should begin only after the technical specification and approved drawings are confirmed by both parties.
Product Enquiry

Define the right product configuration

Share the application and commercial information available at this stage. Our team will review the request against the product range and identify any details still required for quotation.

Application data

Rated voltage, installation environment and operating duty.

Technical scope

Applicable standard, configuration and required documents.

Delivery planning

Estimated quantity, destination and requested schedule.

Project details

Complete the fields below and include any specification points already confirmed.